Description
Underfloor Heating Thermostatic Mixing Valve – UFH Blending Valve
Thermostatic Blending Valve for Water Underfloor Heating Systems
Our Underfloor Heating Thermostatic Mixing Valve is designed to regulate the temperature of water supplied to water-based underfloor heating systems.
By blending hotter water from the primary heating circuit with cooler return water from the underfloor heating system, this UFH blending valve helps maintain a stable and controlled flow temperature before water enters the manifold and heating circuits.
Underfloor heating typically requires lower flow temperatures than conventional radiator systems. A thermostatic mixing valve is therefore an important component in installations where the primary heating water temperature is higher than the temperature required by the underfloor heating circuits.
Factory pre-set to 45°C, the valve can be adjusted during installation and commissioning according to the heating system design and floor construction.
Key Features & Benefits
- Thermostatic Temperature Control: Automatically blends primary and return water to help maintain a consistent UFH flow temperature.
- Factory Pre-set to 45°C: Provides an initial temperature setting that can be adjusted during commissioning.
- Helps Prevent Overheating: Reduces the risk of excessively hot water entering the underfloor heating circuits.
- Suitable for UFH Manifolds: Designed for use with compatible flow and return manifold arrangements.
- Stable Heating Performance: Helps maintain controlled water temperatures as system conditions change.
- Maximum Operating Temperature of 85°C: Suitable for operation within the manufacturer’s stated temperature limits.
- Maximum Static Pressure of 10 Bar: Designed for compatible sealed heating systems operating within the specified pressure limits.
- Replacement or New Installation: Suitable for appropriately designed underfloor heating mixing assemblies.
Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Thermostatic Mixing / Blending Valve |
| Application | Water Underfloor Heating |
| Control Type | Thermostatic Temperature Regulation |
| Factory Temperature Setting | 45°C |
| Adjustable Temperature Range | Refer to confirmed manufacturer specification |
| Maximum Operating Temperature | 85°C |
| Maximum Static Pressure | 10 bar |
| Height | 276mm |
| Width | 155mm |
| Depth | 125mm |
| Manifold Compatibility | Compatible UFH Flow & Return Manifolds |
| Circulation Pump | Not Included |
How Does an Underfloor Heating Mixing Valve Work?
A thermostatic blending valve controls the temperature of water entering the underfloor heating system.
Water from the boiler or primary heating circuit may be hotter than the temperature required by the UFH pipework.
The blending valve mixes this hotter supply water with cooler return water from the underfloor heating circuits, producing a controlled mixed-water temperature.
The circulation pump then moves the water through the manifold and individual heating loops.
As temperatures change, the thermostatic valve adjusts the mixing proportion to help maintain the selected flow temperature.
Why Is a Thermostatic Mixing Valve Important?
Water underfloor heating systems operate most effectively when the flow temperature is matched to the heating design and floor construction.
A correctly selected and adjusted thermostatic mixing valve can help:
- Maintain a controlled UFH flow temperature
- Reduce the risk of excessive floor temperatures
- Support comfortable and consistent heating
- Protect temperature-sensitive floor constructions
- Improve temperature regulation within the heating system
The required water temperature depends on the heat source, pipe spacing, floor covering and heat loss calculations.
Compatibility & Installation
This underfloor heating thermostatic mixing valve is intended for use with compatible water underfloor heating manifold and pump arrangements.
Before ordering, please check:
- The existing mixing valve assembly dimensions
- The required flow and return connections
- Compatibility with the manifold and circulation pump
- The heating system’s operating pressure and temperature
- The required temperature adjustment range
Important: This product is supplied without a circulation pump. The valve must be installed and commissioned according to the manufacturer’s instructions and the underfloor heating system design.
What Is Included?
- Thermostatic mixing / blending valve assembly as shown
Circulation pump not included.
Complete Your Underfloor Heating System
At The Underfloor Heating Expert, we supply a wide range of products for water underfloor heating installations, including:
- Underfloor heating manifolds
- Grundfos and Wilo circulation pumps
- Thermostatic blending valves
- UFH pipes and fittings
- Thermostats and wiring centres
- Underfloor heating installation accessories
Whether you’re replacing an existing blending valve or installing a new water underfloor heating system, our team can help you choose suitable components.
Order your Underfloor Heating Thermostatic Mixing Valve online today.